clarify the last entry in BUGS somewhat, since not all mp machines
will have more than one temperature sensor; ok tedu
Diffstat (limited to 'share')
-rw-r--r--share/man/man4/man4.amd64/cpu.47
-rw-r--r--share/man/man4/man4.i386/cpu.47
2 files changed, 8 insertions, 6 deletions
diff --git a/share/man/man4/man4.amd64/cpu.4 b/share/man/man4/man4.amd64/cpu.4
index ed4e089096f..f556ba50b14 100644
--- a/share/man/man4/man4.amd64/cpu.4
+++ b/share/man/man4/man4.amd64/cpu.4
@@ -1,4 +1,4 @@
-.\" $OpenBSD: cpu.4,v 1.3 2007/10/31 16:25:22 jmc Exp $
+.\" $OpenBSD: cpu.4,v 1.4 2009/07/13 15:43:05 jmc Exp $
.\"
.\" Copyright (c) 2004 Ted Unangst
.\" All rights reserved.
@@ -23,7 +23,7 @@
.\" (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF
.\" THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
.\"
-.Dd $Mdocdate: October 31 2007 $
+.Dd $Mdocdate: July 13 2009 $
.Dt CPU 4 amd64
.Os
.Sh NAME
@@ -63,5 +63,6 @@ processor.
Due to the way in which thermal information is reported on Intel processors,
the temperature may be off by exactly +/-15 degrees C.
.Pp
-For multiprocessor kernels, processors will report identical temperatures
+For multiprocessor kernels with more than one CPU sensor,
+processors will report identical temperatures
since the temperature is taken from the processor running the sensors update.
diff --git a/share/man/man4/man4.i386/cpu.4 b/share/man/man4/man4.i386/cpu.4
index 20ae4c1f00c..f0fec70b497 100644
--- a/share/man/man4/man4.i386/cpu.4
+++ b/share/man/man4/man4.i386/cpu.4
@@ -1,4 +1,4 @@
-.\" $OpenBSD: cpu.4,v 1.15 2007/11/28 17:20:29 tedu Exp $
+.\" $OpenBSD: cpu.4,v 1.16 2009/07/13 15:43:05 jmc Exp $
.\"
.\" Copyright (c) 2004 Ted Unangst
.\" All rights reserved.
@@ -23,7 +23,7 @@
.\" (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF
.\" THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
.\"
-.Dd $Mdocdate: November 28 2007 $
+.Dd $Mdocdate: July 13 2009 $
.Dt CPU 4 i386
.Os
.Sh NAME
@@ -93,5 +93,6 @@ processor.
Due to the way in which thermal information is reported on Intel processors,
the temperature may be off by exactly +/-15 degrees C.
.Pp
-For multiprocessor kernels, processors will report identical temperatures
+For multiprocessor kernels with more than one CPU sensor,
+processors will report identical temperatures
since the temperature is taken from the processor running the sensors update.