diff options
author | Theo de Raadt <deraadt@cvs.openbsd.org> | 1995-10-18 08:53:40 +0000 |
---|---|---|
committer | Theo de Raadt <deraadt@cvs.openbsd.org> | 1995-10-18 08:53:40 +0000 |
commit | d6583bb2a13f329cf0332ef2570eb8bb8fc0e39c (patch) | |
tree | ece253b876159b39c620e62b6c9b1174642e070e /sys/miscfs/portal/portal_vfsops.c |
initial import of NetBSD tree
Diffstat (limited to 'sys/miscfs/portal/portal_vfsops.c')
-rw-r--r-- | sys/miscfs/portal/portal_vfsops.c | 311 |
1 files changed, 311 insertions, 0 deletions
diff --git a/sys/miscfs/portal/portal_vfsops.c b/sys/miscfs/portal/portal_vfsops.c new file mode 100644 index 00000000000..e068a24e559 --- /dev/null +++ b/sys/miscfs/portal/portal_vfsops.c @@ -0,0 +1,311 @@ +/* $NetBSD: portal_vfsops.c,v 1.13 1995/06/18 14:47:35 cgd Exp $ */ + +/* + * Copyright (c) 1992, 1993 + * The Regents of the University of California. All rights reserved. + * + * This code is derived from software donated to Berkeley by + * Jan-Simon Pendry. + * + * Redistribution and use in source and binary forms, with or without + * modification, are permitted provided that the following conditions + * are met: + * 1. Redistributions of source code must retain the above copyright + * notice, this list of conditions and the following disclaimer. + * 2. Redistributions in binary form must reproduce the above copyright + * notice, this list of conditions and the following disclaimer in the + * documentation and/or other materials provided with the distribution. + * 3. All advertising materials mentioning features or use of this software + * must display the following acknowledgement: + * This product includes software developed by the University of + * California, Berkeley and its contributors. + * 4. Neither the name of the University nor the names of its contributors + * may be used to endorse or promote products derived from this software + * without specific prior written permission. + * + * THIS SOFTWARE IS PROVIDED BY THE REGENTS AND CONTRIBUTORS ``AS IS'' AND + * ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE + * IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE + * ARE DISCLAIMED. IN NO EVENT SHALL THE REGENTS OR CONTRIBUTORS BE LIABLE + * FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL + * DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS + * OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) + * HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT + * LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY + * OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF + * SUCH DAMAGE. + * + * from: Id: portal_vfsops.c,v 1.5 1992/05/30 10:25:27 jsp Exp + * @(#)portal_vfsops.c 8.6 (Berkeley) 1/21/94 + */ + +/* + * Portal Filesystem + */ + +#include <sys/param.h> +#include <sys/systm.h> +#include <sys/time.h> +#include <sys/types.h> +#include <sys/proc.h> +#include <sys/filedesc.h> +#include <sys/file.h> +#include <sys/vnode.h> +#include <sys/mount.h> +#include <sys/namei.h> +#include <sys/malloc.h> +#include <sys/mbuf.h> +#include <sys/socket.h> +#include <sys/socketvar.h> +#include <sys/protosw.h> +#include <sys/domain.h> +#include <sys/un.h> +#include <miscfs/portal/portal.h> + +int +portal_init() +{ + + return (0); +} + +/* + * Mount the per-process file descriptors (/dev/fd) + */ +int +portal_mount(mp, path, data, ndp, p) + struct mount *mp; + char *path; + caddr_t data; + struct nameidata *ndp; + struct proc *p; +{ + struct file *fp; + struct portal_args args; + struct portalmount *fmp; + struct socket *so; + struct vnode *rvp; + size_t size; + int error; + + /* + * Update is a no-op + */ + if (mp->mnt_flag & MNT_UPDATE) + return (EOPNOTSUPP); + + if (error = copyin(data, (caddr_t) &args, sizeof(struct portal_args))) + return (error); + + if (error = getsock(p->p_fd, args.pa_socket, &fp)) + return (error); + so = (struct socket *) fp->f_data; + if (so->so_proto->pr_domain->dom_family != AF_UNIX) + return (ESOCKTNOSUPPORT); + + error = getnewvnode(VT_PORTAL, mp, portal_vnodeop_p, &rvp); /* XXX */ + if (error) + return (error); + MALLOC(rvp->v_data, void *, sizeof(struct portalnode), + M_TEMP, M_WAITOK); + + fmp = (struct portalmount *) malloc(sizeof(struct portalmount), + M_UFSMNT, M_WAITOK); /* XXX */ + rvp->v_type = VDIR; + rvp->v_flag |= VROOT; + VTOPORTAL(rvp)->pt_arg = 0; + VTOPORTAL(rvp)->pt_size = 0; + VTOPORTAL(rvp)->pt_fileid = PORTAL_ROOTFILEID; + fmp->pm_root = rvp; + fmp->pm_server = fp; fp->f_count++; + + mp->mnt_flag |= MNT_LOCAL; + mp->mnt_data = (qaddr_t)fmp; + getnewfsid(mp, makefstype(MOUNT_PORTAL)); + + (void) copyinstr(path, mp->mnt_stat.f_mntonname, MNAMELEN - 1, &size); + bzero(mp->mnt_stat.f_mntonname + size, MNAMELEN - size); + (void) copyinstr(args.pa_config, mp->mnt_stat.f_mntfromname, + MNAMELEN - 1, &size); + bzero(mp->mnt_stat.f_mntfromname + size, MNAMELEN - size); + return (0); +} + +int +portal_start(mp, flags, p) + struct mount *mp; + int flags; + struct proc *p; +{ + + return (0); +} + +int +portal_unmount(mp, mntflags, p) + struct mount *mp; + int mntflags; + struct proc *p; +{ + extern int doforce; + struct vnode *rootvp = VFSTOPORTAL(mp)->pm_root; + int error, flags = 0; + + if (mntflags & MNT_FORCE) { + /* portal can never be rootfs so don't check for it */ + if (!doforce) + return (EINVAL); + flags |= FORCECLOSE; + } + + /* + * Clear out buffer cache. I don't think we + * ever get anything cached at this level at the + * moment, but who knows... + */ +#ifdef notyet + mntflushbuf(mp, 0); + if (mntinvalbuf(mp, 1)) + return (EBUSY); +#endif + if (rootvp->v_usecount > 1) + return (EBUSY); + if (error = vflush(mp, rootvp, flags)) + return (error); + + /* + * Release reference on underlying root vnode + */ + vrele(rootvp); + /* + * And blow it away for future re-use + */ + vgone(rootvp); + /* + * Shutdown the socket. This will cause the select in the + * daemon to wake up, and then the accept will get ECONNABORTED + * which it interprets as a request to go and bury itself. + */ + soshutdown((struct socket *) VFSTOPORTAL(mp)->pm_server->f_data, 2); + /* + * Discard reference to underlying file. Must call closef because + * this may be the last reference. + */ + closef(VFSTOPORTAL(mp)->pm_server, (struct proc *) 0); + /* + * Finally, throw away the portalmount structure + */ + free(mp->mnt_data, M_UFSMNT); /* XXX */ + mp->mnt_data = 0; + return (0); +} + +int +portal_root(mp, vpp) + struct mount *mp; + struct vnode **vpp; +{ + struct vnode *vp; + + /* + * Return locked reference to root. + */ + vp = VFSTOPORTAL(mp)->pm_root; + VREF(vp); + VOP_LOCK(vp); + *vpp = vp; + return (0); +} + +int +portal_quotactl(mp, cmd, uid, arg, p) + struct mount *mp; + int cmd; + uid_t uid; + caddr_t arg; + struct proc *p; +{ + + return (EOPNOTSUPP); +} + +int +portal_statfs(mp, sbp, p) + struct mount *mp; + struct statfs *sbp; + struct proc *p; +{ + +#ifdef COMPAT_09 + sbp->f_type = 12; +#else + sbp->f_type = 0; +#endif + sbp->f_bsize = DEV_BSIZE; + sbp->f_iosize = DEV_BSIZE; + sbp->f_blocks = 2; /* 1K to keep df happy */ + sbp->f_bfree = 0; + sbp->f_bavail = 0; + sbp->f_files = 1; /* Allow for "." */ + sbp->f_ffree = 0; /* See comments above */ + if (sbp != &mp->mnt_stat) { + bcopy(&mp->mnt_stat.f_fsid, &sbp->f_fsid, sizeof(sbp->f_fsid)); + bcopy(mp->mnt_stat.f_mntonname, sbp->f_mntonname, MNAMELEN); + bcopy(mp->mnt_stat.f_mntfromname, sbp->f_mntfromname, MNAMELEN); + } + strncpy(sbp->f_fstypename, mp->mnt_op->vfs_name, MFSNAMELEN); + return (0); +} + +int +portal_sync(mp, waitfor) + struct mount *mp; + int waitfor; +{ + + return (0); +} + +int +portal_vget(mp, ino, vpp) + struct mount *mp; + ino_t ino; + struct vnode **vpp; +{ + + return (EOPNOTSUPP); +} + +int +portal_fhtovp(mp, fhp, vpp) + struct mount *mp; + struct fid *fhp; + struct vnode **vpp; +{ + + return (EOPNOTSUPP); +} + +int +portal_vptofh(vp, fhp) + struct vnode *vp; + struct fid *fhp; +{ + + return (EOPNOTSUPP); +} + +struct vfsops portal_vfsops = { + MOUNT_PORTAL, + portal_mount, + portal_start, + portal_unmount, + portal_root, + portal_quotactl, + portal_statfs, + portal_sync, + portal_vget, + portal_fhtovp, + portal_vptofh, + portal_init, +}; |