diff options
author | Reyk Floeter <reyk@cvs.openbsd.org> | 2006-12-16 11:52:52 +0000 |
---|---|---|
committer | Reyk Floeter <reyk@cvs.openbsd.org> | 2006-12-16 11:52:52 +0000 |
commit | 617b8661abd46c04fb9d587dae54151eb714caf4 (patch) | |
tree | 7f4eb8b7e30ad06f4ff94978c0420240a2e4fcd2 /usr.sbin/relayd/relayd.conf.5 | |
parent | 319dc70a11cfb560818c33b6c310d8b68a825ae6 (diff) |
new sentence, new line
Diffstat (limited to 'usr.sbin/relayd/relayd.conf.5')
-rw-r--r-- | usr.sbin/relayd/relayd.conf.5 | 36 |
1 files changed, 20 insertions, 16 deletions
diff --git a/usr.sbin/relayd/relayd.conf.5 b/usr.sbin/relayd/relayd.conf.5 index 349dce672b4..8e243e50a40 100644 --- a/usr.sbin/relayd/relayd.conf.5 +++ b/usr.sbin/relayd/relayd.conf.5 @@ -1,4 +1,4 @@ -.\" $OpenBSD: relayd.conf.5,v 1.1 2006/12/16 11:45:07 reyk Exp $ +.\" $OpenBSD: relayd.conf.5,v 1.2 2006/12/16 11:52:51 reyk Exp $ .\" .\" Copyright (c) 2006 Pierre-Yves Ritschard <pyr@spootnik.org> .\" @@ -82,7 +82,8 @@ The default interval is 10 seconds. .El .Sh TABLES Tables are used to group a set of hosts that can be checked using the same -method. Only one health-checking method can be used per table. +method. +Only one health-checking method can be used per table. Table specific configuration directives are described below. .Bl -tag -width Ds .It Ic check tcp @@ -100,26 +101,27 @@ gives the HTTP return code For each host in the table, verify that retrieving the URL .Ar path produces a content whose SHA1 digest is -.Ar digest -. The digest does not take the HTTP headers into account. To compute the -digest you can use this simple command: +.Ar digest . +The digest does not take the HTTP headers into account. +To compute the digest you can use this simple command: .Bd -literal -offset 2n ftp -o - http://host[:port]/path | sha1 - .Ed +.Pp This will give you a digest of the form .Bd -literal -offset 2n a9993e36476816aba3e25717850c26c9cd0d89d - .Ed +.Pp that you can use as-is in your digest statement. .It Ic timeout Ar number Set the timeout in milliseconds for each host that is checked. The default timeout is 200 milliseconds. .It Ic real port Ar number When using the tcp or http checking methods, use this port to connect -to hosts. This parameter is mandatory. Main and backup tables need -to have the same real port. +to hosts. +This parameter is mandatory. +Main and backup tables need to have the same real port. .It Ic host Ar address Add the host whose address is .Ar address @@ -140,25 +142,27 @@ below. .Bl -tag -width Ds .It Ic virtual ip Ar address Ic port Ar number Specify an address and a port that will be used to redirect requests -to the hosts in the main or backup table. -Optionally an interface name can be specified like this +to the hosts in the main or backup table. +Optionally an interface name can be specified like this. .Bd -literal -offset indent interface ``ifname'' - .Ed +.Pp to specify which interface the rdr rule will be enabled on. .It Ic table Ar name -Specify the main table to be used. This is mandatory. +Specify the main table to be used. +This is mandatory. .It Ic backup table Ar name Specify the table to switch to when all hosts in the main table are seen as down or disabled. .It Ic disable -Set the service initially disabled. It can be later enabled through +Set the service initially disabled. +It can be later enabled through .It Ic tag Ar name Automatically tag packets passing through the .Xr pf 4 -rdr rule with the name supplied. This allows for easier filter rules -in your main +rdr rule with the name supplied. +This allows for easier filter rules in your main .Xr pf 4 configuration. .Xr hostatectl 5 . |