.\" $OpenBSD: ccdconfig.8,v 1.5 1996/10/08 01:20:22 michaels Exp $ .\" $NetBSD: ccdconfig.8,v 1.4 1996/02/28 01:01:17 thorpej Exp $ .\" .\" Copyright (c) 1996 The NetBSD Foundation, Inc. .\" All rights reserved. .\" .\" This code is derived from software contributed to The NetBSD Foundation .\" by Jason R. Thorpe. .\" .\" Redistribution and use in source and binary forms, with or without .\" modification, are permitted provided that the following conditions .\" are met: .\" 1. Redistributions of source code must retain the above copyright .\" notice, this list of conditions and the following disclaimer. .\" 2. Redistributions in binary form must reproduce the above copyright .\" notice, this list of conditions and the following disclaimer in the .\" documentation and/or other materials provided with the distribution. .\" 3. All advertising materials mentioning features or use of this software .\" must display the following acknowledgement: .\" This product includes software developed by the NetBSD .\" Foundation, Inc. and its contributors. .\" 4. Neither the name of The NetBSD Foundation nor the names of its .\" contributors may be used to endorse or promote products derived .\" from this software without specific prior written permission. .\" .\" THIS SOFTWARE IS PROVIDED BY THE NETBSD FOUNDATION, INC. AND CONTRIBUTORS .\" ``AS IS'' AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED .\" TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR .\" PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE REGENTS OR CONTRIBUTORS BE .\" LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR .\" CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF .\" SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS .\" INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN .\" CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) .\" ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE .\" POSSIBILITY OF SUCH DAMAGE. .\" .Dd July 17, 1995 .Dt CCDCONFIG 8 .Os .Sh NAME .Nm ccdconfig .Nd configuration utility for the concatenated disk driver .Sh SYNOPSIS .Nm ccdconfig .Op Fl cv .Ar ccd .Ar ileave .Op Ar flags .Ar dev .Op Ar ... .Nm ccdconfig .Fl C .Op Fl v .Op Fl f Ar config_file .Nm ccdconfig .Fl u .Op Fl v .Ar ccd .Op Ar ... .Nm ccdconfig .Fl U .Op Fl v .Op Fl f Ar config_file .Nm ccdconfig .Fl g .Op Fl M Ar core .Op Fl N Ar system .Oo .Ar ccd Oo ... .Oc .Oc .Sh DESCRIPTION .Nm Ccdconfig is used to dynamically configure and unconfigure concatenated disk devices, or ccds. For more information about the ccd, see .Xr ccd 4 . .Pp The options are as follows: .Bl -tag -width indent .It Fl c Configure a ccd. This is the default behavior of .Nm ccdconfig . .It Fl C Configure all ccd devices listed in the ccd configuration file. .It Fl f Ar config_file When configuring or unconfiguring all devices, read the file .Pa config_file instead of the default .Pa /etc/ccd.conf . .It Fl g Dump the current ccd configuration in a format suitable for use as the ccd configuration file. If no arguments are specified, every configured ccd is dumped. Otherwise, the configuration of each listed ccd is dumped. .It Fl M Ar core Extract values associated with the name list from .Pa core instead of the default .Pa /dev/mem . .It Fl N Ar system Extract the name list from .Pa system instead of the default .Pa /bsd . .It Fl u Unconfigure a ccd. .It Fl U Unconfigure all ccd devices listed the ccd configuration file. .It Fl v Causes .Nm ccdconfig to be verbose. .El .Pp A ccd is described on the command line and in the ccd configuration file by the name of the ccd, the interleave factor, the ccd configuration flags, and a list of one or more devices. The flags may be represented as a decimal number, a hexadecimal number, a comma-separated list of strings, or the word .Dq none . The flags are as follows: .Bd -unfilled -offset indent CCDF_SWAP 0x01 Interleave should be dmmax CCDF_UNIFORM 0x02 Use uniform interleave CCDF_MIRROR 0x04 Enable data mirroring .Ed .Pp The format in the configuration file appears exactly as if it were entered on the command line. Note that on the command line and in the configuration file, the .Pa flags argument is optional. .Bd -unfilled -offset indent # # /etc/ccd.conf # Configuration file for concatenated disk devices # .Pp # ccd ileave flags component devices ccd0 16 none /dev/sd2e /dev/sd3e .Ed .Pp .Sh EXAMPLE The following command, executed from the command line, would configure ccd0 with 4 components (/dev/sd2e, /dev/sd3e, /dev/sd4e, /dev/sd5e), and an interleave factor of 32 blocks. .Bd -unfilled -offset indent # ccdconfig ccd0 32 0 /dev/sd2e /dev/sd3e /dev/sd4e /dev/sd5e .Ed .Pp .Sh FILES /etc/ccd.conf - default ccd configuration file. .Sh SEE ALSO .Xr ccd 4 , .Xr rc 8 . .Sh HISTORY The .Nm ccdconfig command first appeared in .Nx 1.0a .