.\" $OpenBSD: pdc.4,v 1.3 2005/02/27 09:04:03 david Exp $ .\" .\" Copyright (c) 2004 Michael Shalayeff .\" All rights reserved. .\" .\" Redistribution and use in source and binary forms, with or without .\" modification, are permitted provided that the following conditions .\" are met: .\" 1. Redistributions of source code must retain the above copyright .\" notice, this list of conditions and the following disclaimer. .\" 2. Redistributions in binary form must reproduce the above copyright .\" notice, this list of conditions and the following disclaimer in the .\" documentation and/or other materials provided with the distribution. .\" .\" THIS SOFTWARE IS PROVIDED BY THE AUTHOR ``AS IS'' AND ANY EXPRESS OR .\" IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES .\" OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. .\" IN NO EVENT SHALL THE AUTHOR OR HIS RELATIVES BE LIABLE FOR ANY DIRECT, .\" INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES .\" (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR .\" SERVICES; LOSS OF MIND, USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) .\" HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, .\" STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING .\" IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF .\" THE POSSIBILITY OF SUCH DAMAGE. .\" .Dd September 13, 2004 .Dt PDC 4 hppa .Os .Sh NAME .Nm pdc .Nd Processor-Dependent Code firmware driver .Sh SYNOPSIS .Cd "pdc0 at mainbus?" .Sh DESCRIPTION The .Nm driver provides system console services through the PDC and also a means for calling PDC procedures, described later. The PDC console is used early in the kernel startup before enough kernel subsystems have been initialized to directly use the hardware i.e. serial ports, keyboard, and video. .Pp The PDC version displayed at system boot is relevant to the particular system model and is not necessarily comparable to PDC versions on other systems. .\" TODO page0 description and entry points .Sh PDC PROCEDURES PDC procedure calls are all made through a single entry point and assume normal C language calling conventions, with option number in the first argument and the return data address in the second, unless indicated otherwise. Each call requires at most 7KB of the available stack. Here is the list of procedures and options descriptions: .Bl -tag -width pdc .It Fn pdc "PDC_ADD_VALID" "PDC_ADD_VALID_DFLT" "paddr" Perform a read operation attempt at the physical address .Ar paddr without causing a HPMC, in order to verify that the address is valid and there is a device to respond to it. The implementation may choose to call the caller's HPMC handler and raise error conditions on the bus convertors. .It Fn pdc "PDC_ALLOC" "PDC_ALLOC_DFLT" "ptr" "size" Allocate static storage for IODC use of .Ar size bytes and return the address in a word pointed to by the .Ar ptr argument. There is no way of freeing the storage allocated and thus care shall be taken to not exhaust the total allocation limit of 32KB. .It Fn pdc "PDC_BLOCK_TLB" "PDC_BTLB_DEFAULT" "ptr" Get block TLB parameters into the data area pointed to by the .Ar ptr argument. This includes minimal and maximal entry size and number of fixed and variable sized entries in the block TLB. Fixed entries have size of power of two and are aligned to the size where variable entries can have any size and base address both aligned to a page. .It Xo .Fo pdc .Fa PDC_BLOCK_TLB .Fa PDC_BTLB_INSERT .Fa sp .Fa va .Fa pa .Fa len .Fa acc .Fa slot .Fc .Xc Insert block TLB entry specified by the space ID .Ar sp , virtual address .Ar va , physicall address .Ar pa , region length .Ar len , access rights .Ar acc , into the slot number .Ar slot . .It Fn pdc "PDC_BLOCK_TLB" "PDC_BTLB_PURGE" "sp" "va" "slot" "len" Purge one entry from the block TLB specified by the space ID .Ar sp , virtual address .Ar va , region length .Ar len , from slot number .Ar slot . .It Fn pdc "PDC_BLOCK_TLB" "PDC_BTLB_PURGE_ALL" Purge all entries from the block TLB. .\" TODO .It Fn pdc "PDC_BUS_BAD" "PDC_BUS_BAD_DLFT" .It Fn pdc "PDC_CACHE" "PDC_CACHE_DFLT" "ptr" Retrieve cache and TLB configuration parameters into the data area pointed to by the .Ar ptr argument. The format of the data stores is as follows: .Bl -column "0x00" "contents" -offset left .It Sy "addr" Ta Sy "contents" .It "0x00" Ta "I-cache size in bytes" .It "0x04" Ta "I-cache configuration" .It "0x08" Ta "I-cache base for flushing" .It "0x0c" Ta "I-cache stride for flushing" .It "0x10" Ta "I-cache count for flushing" .It "0x14" Ta "I-cache loop size for flushing" .It "0x18" Ta "D-cache size in bytes" .It "0x1c" Ta "D-cache configuration" .It "0x20" Ta "D-cache base for flushing" .It "0x24" Ta "D-cache stride for flushing" .It "0x28" Ta "D-cache count for flushing" .It "0x2c" Ta "D-cache loop size for flushing" .It "0x30" Ta "ITLB size" .It "0x34" Ta "ITLB configuration" .It "0x38" Ta "ITLB space base for flushing" .It "0x3c" Ta "ITLB space stride for flushing" .It "0x40" Ta "ITLB space count for flushing" .It "0x44" Ta "ITLB address base for flushing" .It "0x48" Ta "ITLB address stride for flushing" .It "0x4c" Ta "ITLB address count for flushing" .It "0x50" Ta "ITLB loop size for flushing" .It "0x54" Ta "DTLB size" .It "0x58" Ta "DTLB configuration" .It "0x5c" Ta "DTLB space base for flushing" .It "0x60" Ta "DTLB space stride for flushing" .It "0x64" Ta "DTLB space count for flushing" .It "0x68" Ta "DTLB address base for flushing" .It "0x6c" Ta "DTLB address stride for flushing" .It "0x70" Ta "DTLB address count for flushing" .It "0x74" Ta "DTLB loop size for flushing" .El .Pp The cache configuration word is formatted as follows: .Bl -column "bit" "len" "contents" -offset left .It Sy "bit" "len" "contents" .It "0" "12" "reserved" .It "13" "3" "set 1 if coherent operation supported" .It "16" "2" "flush mode: 0 -- fdc & fic; 1 -- fdc; 2 -- fic; 3 -- either" .It "18" "1" "write-thru D-cache if set" .It "19" "2" "reserved" .It "21" "3" "cache line size" .It "24" "4" "associativity" .It "28" "4" "virtual address alias boundary" .El .Pp .It Fn pdc "PDC_CACHE" "PDC_CACHE_SETCS" "ptr" "i_cst" "d_cst" "it_cst" "dt_cst" The second word in each of the .Ar i_cst , .Ar d_cst , .Ar it_cst , and .Ar dt_cst arguments specifies the desired coherency operation for the instructions cache, data cache, instructions TLB, and data TLB, respectively. The data area pointed to by the .Ar ptr argument receives the actual coherent operation state after an attempted change. The CPU does not support the requested operation change should the corresponding words not match the arguments upon return. The currently supported values are zero for incoherent operation, and one for coherent operation. .It Fn pdc "PDC_CACHE" "PDC_CACHE_GETSPIDB" "ptr" The word pointed to by the .Ar ptr argument receives a mask of space ID used in hashing for cache tag. .It Fn pdc "PDC_CHASSIS" "PDC_CHASSIS_DISP" "display" Update the chassis display with data given in the .Ar display argument. The bitfields in the word are as follows: .Pp .Bl -tag -width 0xfffff -compact .It 0xe0000 Specifies the system state. .Bl -tag -width 0xfffff -compact .It 0x00000 off .It 0x20000 fault .It 0x40000 test .It 0x60000 initialize .It 0x80000 shutdown .It 0xa0000 warning .It 0xc0000 run .It 0xe0000 all on .El .It 0x10000 Blank the chassis display. .It 0x0f000 This and the other lower three nibbles specify the four hex digits to be displayed on the chassis display. .El .It Fn pdc "PDC_CHASSIS" "PDC_CHASSIS_WARN" "ptr" Return the warnings from the chassis fans, temperature sensors, batteries and power supplies. A word of data is returned in the area pointed by the .Ar ptr argument and is described with bitfields: .Pp .Bl -tag -width 0xff -compact .It 0xff000000 Zero means none of the redundant chassis components has indicated any failures. A non-zero value specifies the failing component. .It 0x4 Indicates the chassis battery charge is low. .It 0x2 The chassis temperature has exceeded the low threshold. .It 0x1 The chassis temperature has exceeded the middle threshold. .El .It Fn pdc "PDC_CHASSIS" "PDC_CHASSIS_ALL" "ptr" "display" Both retreives the chassis warnings into the word pointed by the .Ar ptr argument and sets the chassis display using data in the .Ar display argument. .\" TODO .It Fn pdc "PDC_CONF" "PDC_CONFIG_DECONF" "ptr" "hpa" .\" TODO .It Fn pdc "PDC_CONF" "PDC_CONFIG_RECONF" "ptr" "hpa" .\" TODO .It Fn pdc "PDC_CONF" "PDC_CONFIG_INFO" "ptr" "hpa" .It Fn pdc "PDC_COPROC" "PDC_COPROC_DFLT" "ptr" Identify the coprocessors attached to the CPU. The .Ar ptr points to a memory location where data is to be stored. The first word provides a mask for functional coprocessors and the second word is the mask for all present coprocessors. .It Fn pdc "PDC_DEBUG" "PDC_DEBUG_DFLT" "ptr" Retrieve address of the PDC debugger placed in to the word pointed to by the .Ar ptr argument. .\" TODO .It Fn pdc "PDC_INSTR" "PDC_INSTR_DFLT" .It Fn pdc "PDC_IODC" "PDC_IODC_READ" "ptr" "hpa" "entry" "addr" "count" Given a module .Ar hpa , retrieve the specified .Ar entry from the module's IODC into a memory area at .Ar adr of .Ar count bytes long at most. The .Ar entry index is a one-byte index, with a value of zero being a special case. For the 0th entry, an IODC header of 16 bytes is returned instead of an actual code. .It Fn pdc "PDC_IODC" "PDC_IODC_NINIT" "ptr" "hpa" "spa" Non-destructively initialize the memory module specified by the .Ar hpa and .Ar spa arguments and return the module status after the init in the first word pointed to by the .Ar ptr argument, followed by the SPA space size and an amount of available memory bytes in the subsequent two words. .It Fn pdc "PDC_IODC" "PDC_IODC_DINIT" "ptr" "hpa" "spa" Same as .Nm PDC_IODC_NINIT except a destructive memory test is performed. .It Fn pdc "PDC_IODC" "PDC_IODC_MEMERR" "ptr" "hpa" "spa" For the memory module that is specified by .Ar hpa and .Ar spa , return the last most severe error information comprised of copies of IO_STATUS, IO_ERR_RESP, IO_ERR_INFO, and IO_ERR_REQ registers placed into the data area pointed to by the .Ar ptr argument, and clear the error status. .It Fn pdc "PDC_IODC" "PDC_IODC_IMEMMASTER" "ptr" "hpa" HPA for the primary memory module is returned in a word pointed to by the .Ar ptr argument for a memory module specified by .Ar hpa if it's configured as a slave module in an interleave group. .It Fn pdc "PDC_LAN_STATION_ID" "PDC_LAN_STATION_ID_READ" "macptr" "hpa" Retrieve the MAC address for the device at .Ar hpa into the data area pointed to by the .Ar macptr argument. .\" TODO .It Fn pdc "PDC_MEM" "PDC_MEM_INFO" "ptr" .\" TODO .It Fn pdc "PDC_MEM" "PDC_MEM_ADD" "ptr" "PDT" .\" TODO .It Fn pdc "PDC_MEM" "PDC_MEM_CLR" "ptr" .\" TODO .It Fn pdc "PDC_MEM" "PDC_MEM_READ" "ptr" "PDT" .\" TODO .It Fn pdc "PDC_MEM" "PDC_MEM_RSTCLR" "ptr" .\" TODO .It Fn pdc "PDC_MEM" "PDC_MEM_SETGOOD" "ptr" "good" .It Fn pdc "PDC_MEMMAP" "PDC_MEMMAP_HPA." "ptr" "path" Returns device HPA in the word pointed to by the .Ar ptr argument given the device .Ar path pointer. .It Fn pdc "PDC_MODEL" "PDC_MODEL_INFO" "ptr" Returns the System model numbers. .It Fn pdc "PDC_MODEL" "PDC_MODEL_BOOTID" "boot_id" Set BOOT_ID of the processor module (used during boot process of monarch selection) to a word given in the .Ar boot_id argument. .It Fn pdc "PDC_MODEL" "PDC_MODEL_COMP" "ptr" "index" Retrieve processor component versions by issuing this procedure with subsequent indexes in the .Ar index argument starting at zero. The component version number is stored in the word pointed to by the .Ar ptr argument. .It Fn pdc "PDC_MODEL" "PDC_MODEL_MODEL" "ptr" "os_id" "mod_addr" Return a string of 80 chars maximum stored at address .Ar mod_addr and conforming to the OS specified by the .Ar os_id 16-bit integer (see .Nm PDC_STABLE for more information on OS ID). A word at the .Ar ptr address receives the result string length. .\" TODO .It Fn pdc "PDC_MODEL" "PDC_MODEL_ENSPEC" "ptr" .\" TODO .It Fn pdc "PDC_MODEL" "PDC_MODEL_DISPEC" "ptr" .It Fn pdc "PDC_MODEL" "PDC_MODEL_CPUID" "ptr" Retrieve CPU model information. A word stored at the address given by the .Ar ptr argument specifies the CPU revision in the lower 5 bits followed by 7 bits of CPU model number. .It Fn pdc "PDC_MODEL" "PDC_MODEL_CPBALITIES" "ptr" Retrieve platform capabilities into the word pointed by the .Ar ptr argument. Bit 0 and 1 specify that a 64- or 32-bit OS is supported, respectively. .It Fn pdc "PDC_MODEL" "PDC_MODEL_GETBOOTOPTS" "ptr" Retrieve the currently enabled, overall supported, and enabled by default boot test masks respectively stored at location pointed to by the .Ar ptr argument. .It Fn pdc "PDC_MODEL" "PDC_MODEL_SETBOOTOPTS" "ptr" "disable" "enable" Disable boot tests specified by mask in the .Ar disable argument and enable boot tests specified by the mask given in the .Ar enable argument. The memory location pointed to by .Ar ptr will contain the resulting masks as returned by the PDC_MODEL_GETBOOTOPTS function. If an attempt is made to enable and disable the same test in one call a PDC_ERR_INVAL will be returned. .It Fn pdc "PDC_NVM" "PDC_NVM_READ" "offset" "ptr" "count" Read contents of the NVM at .Ar offset into the memory area pointed to by the .Ar ptr argument of no more than .Ar count bytes. .Pp The format of the NVM is as follows: .Bl -column "0x0000" "size" "contents" -offset left .It Sy "offset" Ta Sy "size" Ta Sy "contents" .It "0x00" Ta "0x24" Ta "HV dependent" .It "0x24" Ta "0x20" Ta "bootpath" .It "0x44" Ta "0x04" Ta "ISL revision" .It "0x48" Ta "0x04" Ta "timestamp" .It "0x4c" Ta "0x30" Ta "LIF utility entries" .It "0x7c" Ta "0x04" Ta "entry point" .It "0x80" Ta "0x80" Ta "OS panic information" .El .It Fn pdc "PDC_NVM" "PDC_NVM_WRITE" "offset" "ptr" "count" Write data pointed to by the .Ar ptr argument of .Ar count bytes at .Ar address in the NVM. .It Fn pdc "PDC_NVM" "PDC_NVM_SIZE" "ptr" Put the size of Non-Volatile Memory into the word pointed to by the .Ar ptr argument. .It Fn pdc "PDC_NVM" "PDC_NVM_VRFY" Verify that the contents of NVM are valid. .It Fn pdc "PDC_NVM" "PDC_NVM_INIT" Reset the contents of NVM to zeroes without any arguments. .It Fn pdc "PDC_HPA" "PDC_HPA_DFLT" "ptr" The data returned provides the monarch CPUs HPA in the word pointed to by .Ar ptr . .It Fn pdc "PDC_HPA" "PDC_HPA_MODULES" "ptr" Retrieve the bit mask for devices on the CPU bus into the data location pointed to by .Ar ptr . The first word is a bitmask for devices 0-31, and the second is a bitmask for devices 32-63, where bits set to one specify that the corresponding device number is on the same bus as the CPU. .\" TODO .It Fn pdc "PDC_PAT_IO" "PDC_PAT_IO_GET_PCI_RTSZ" .\" TODO .It Fn pdc "PDC_PAT_IO" "PDC_PAT_IO_GET_PCI_RT" .It Fn pdc "PDC_PIM" "PDC_PIM_HPMC" "offset" "ptr" "count" Get HPMC data from .Ar offset in Processor Internal Memory (PIM) into a .Ar ptr memory area of no more than .Ar count bytes in size. Data provided includes (in the order it is copied into the buffer): general registers (r0-r31), control registers (cr0-cr31), space registers (sr0-sr7), IIA space tail, IIA offset tail, check type, CPU state, cache check, TLB check, bus check, assist check, assist state, path info, system responder address, system requestor address, FPU registers (fpr0-fpr31). .It Fn pdc "PDC_PIM" "PDC_PIM_SIZE" "ptr" Return the amount of data available in bytes in the word pointed to by .Ar ptr . .It Fn pdc "PDC_PIM" "PDC_PIM_LPMC" "offset" "ptr" "count" Get LPMC data from .Ar offset in PIM into a .Ar ptr memory area of no more than .Ar count bytes in size. Data provided includes: HV dependent 0x4a words, check type, HV dependent word, cache check, TLB check, bus check, assist check, assist state, path info, system responder address, system requestor address, FPU registers (fpr0-fpr31). .It Fn pdc "PDC_PIM" "PDC_PIM_SBD" "offset" "ptr" "count" Get Soft Boot Data from .Ar offset in PIM into a .Ar ptr memory area of no more than .Ar count bytes in size. Data provided includes: general registers (r0-r31), control registers (cr0-cr31), space registers (sr0-sr7), IIA space tail, IIA offset tail, HV dependent word, CPU state. .It Fn pdc "PDC_PIM" "PDC_PIM_TOC" "offset" "ptr" "count" Get TOC (Transfer Of Control) data from .Ar offset in PIM into a .Ar ptr memory area of no more than .Ar count bytes in size. Data provided includes: general registers (r0-r31), control registers (cr0-cr31), space registers (sr0-sr7), IIA space tail, IIA offset tail, HV dependent word, CPU state. .It Fn pdc "PDC_POW_FAIL" "PDC_POW_FAIL_DFLT" Prepare for power fail. On the machines that provide power failure interrupts, this function is to be called after the operating system has completed .Xr shutdown 8 to finish system-dependent tasks and power down. This function only requires 512 bytes of stack. .It Fn pdc "PDC_PROC" "PDC_PROC_STOP" Stop the currently executing processor and also disable bus requestorship, disable interrupts, and exclude the processor from cache coherency protocols. The caller must flush any necessary data from the cache before calling this function. .It Fn pdc "PDC_PROC" "PDC_PROC_RENDEZVOUS" Enter the reset rendezvous code on the current processor. This function is only implemented on category B processors and implementation is optional on category A processors. .It Fn pdc "PDC_PSW" "PDC_PSW_GETMASK" "ptr" Get the mask of default bits implemented into a word pointed to by the .Ar ptr argument. The following mask values are possible: .Pp .Bl -tag -width 100 -compact .It 1 Default endianess bit is available. .It 2 Default word width bit is available. .El .It Fn pdc "PDC_PSW" "PDC_PSW_DEFAULTS" "ptr" Retrieve the default PSW bits into the word pointed to by the .Ar ptr argument. .It Fn pdc "PDC_PSW" "PDC_PSW_SETDEFAULTS" "bits" Set the default PSW .Ar bits . .It Fn pdc "PDC_SOFT_POWER" "PDC_SOFT_POWER_INFO" "ptr" Retrieve .Dq power register address into the word pointed to by the .Ar ptr argument. Bit-0 in the .Dq power register address being set specifies the power button being depressed. No dampening is required, unlike with the .Xr lasi 4 power circuit. .It Fn pdc "PDC_SOFT_POWER" "PDC_SOFT_POWER_ENABLE" "ptr" "stat" Enable (zero .Ar stat ) or disable (non-zero .Ar stat ) the soft power function, where disable means the machine will turn immediately off should the power get depressed. The .Ar ptr argument still points to the data provided previously by the PDC_SOFT_POWER_INFO call. .It Fn pdc "PDC_STABLE" "PDC_STABLE_READ" "offset" "ptr" "count" Read contents of the .Dq Stable Storage at .Ar offset into the memory area pointed to by the .Ar ptr argument of no more than .Ar count bytes. .Pp The format of the stable storage is as follows: .Bl -column "offset" "0x00" "contents" -offset left .It Sy "offset" "size" "contents" .It "0x0000" "0x20" "primary bootpath" .It "0x0020" "0x20" "reserved" .It "0x0040" "0x02" "OS ID" .It "0x0042" "0x16" "OS dependent" .It "0x0058" "0x02" "diagnostic" .It "0x005a" "0x03" "reserved" .It "0x005d" "0x02" "OS dependent .It "0x005f" "0x01" "fast size" .It "0x0060" "0x20" "console path" .It "0x0080" "0x20" "alternative boot path" .It "0x00a0" "0x20" "keyboard path" .It "0x00c0" "0x20" "reserved" .It "0x00e0" "size" "OS dependent" .El .Pp The .Dq OS ID field may have the following values: .Bl -column "value" "OS" -offset left .It Sy "value" "OS" .It "0x000" "No OS-dependent info" .It "0x001" "HP-UX" .It "0x002" "MPE-iX" .It "0x003" "OSF" .It "0x004" "HP-RT" .It "0x005" "Novell Netware" .El .Pp The .Dq fast size field is the amount of memory to be tested upon system boot and is a power of two multiplier for 256KB. Values of 0xe and 0xf are reserved. .It Fn pdc "PDC_STABLE" "PDC_STABLE_WRITE" "address" "ptr" "count" Write data pointed to by the .Ar ptr argument of .Ar count bytes at .Ar address in the .Dq Stable Storage . .It Fn pdc "PDC_STABLE" "PDC_STABLE_SIZE" "ptr" Put the size of the .Dq Stable Storage into the word pointed to by the .Ar ptr argument. .It Fn pdc "PDC_STABLE" "PDC_STABLE_VRFY" "ptr" Verify that the contents of the .Dq Stable Storage are valid. .It Fn pdc "PDC_STABLE" "PDC_STABLE_INIT" "ptr" Reset the contents of the .Dq Stable Storage to zeroes. .It Fn pdc "PDC_SYSMAP" "PDC_SYSMAP_FIND" "ptr" "path" "number" Map module .Ar number into HPA and also provide an area size starting at HPA and a number of additional addresses placed into the data area pointed to by the .Ar ptr argument words one, two, and three, respectively. The device path is placed into the data area pointed to by the .Ar path argument. .It Fn pdc "PDC_SYSMAP" "PDC_SYSMAP_ADDR" "ptr" "im" "ia" Retrieve a list of additional addresses for the module number .Ar im for the address index .Ar ia . The result is placed into the data area pointed to by .Ar ptr , where the first word gives the address and the second the size of the area. .It Fn pdc "PDC_SYSMAP" "PDC_SYSMAP_HPA" "ptr" "path_ptr" Map device .Ar path_ptr into device's HPA placed into a word pointed to by the .Ar ptr argument. .It Fn pdc "PDC_TLB" "PDC_TLB_INFO" "ptr" Retrieve the hardware TLB handler parameters. This includes a minimal and maximal size for the page table, in bytes, stored into words zero and one, respectively, in the data area pointed to by the .Ar ptr argument. .It Fn pdc "PDC_TLB" "PDC_TLB_CONFIG" "ptr" "base" "size" "param" Configure the hardware TLB miss handler given the same parameters fetched previously with PDC_TLB_INFO into data area pointed to by the .Ar ptr and page table .Ar base address, page table .Ar size , and handler parameters .Ar param . The hardware TLB handler parameter bits are as follows: .Pp .Bl -tag -width 0xff -compact .It 1 Enable the hardware TLB miss handler. The default is to load cr28 with the faulted page table entry address. .It 4 Pointer to the next page table entry is put into cr28. .It 6 Next pointer field of the page table entry is put into cr28. .El .Pp Resetting the page table address and/or size without disabling the hardware TLB miss handler is allowed. Any changes made are immediate upon Code or Data virtual address translation bits are set in PSW. .It Fn pdc "PDC_TOD" "PDC_TOD_READ" "ptr" Read the TOD, which is a UNIX Epoch time, into the data area pointed to by the .Ar ptr argument. That includes seconds in the first word and microseconds in the second. .It Fn pdc "PDC_TOD" "PDC_TOD_WRITE" "sec" "usec" Write TOD with UNIX Epoch time with .Ar sec seconds and .Ar usec microseconds. .It Fn pdc "PDC_TOD" "PDC_TOD_ITIMER" "ptr" Get TOD and CPU timer accuracy into the data location pointed to by the .Ar ptr argument. The first two words specify a double floating-point value giving CPU timer frequency. The next two words provide accuracy in parts per billion for the TOD and CPU timer, respectively. .El .Sh FILES .Bl -tag -width /sys/arch/hppa/dev/cpudevs -compact .It machine/pdc.h C header file with relevant definitions. .It /sys/arch/hppa/dev/cpudevs System components' version numbers. .It /dev/console System console device. .El .Sh DIAGNOSTICS Upon successfull completion all procedures return zero. The following error codes are returned in case of failures: .Pp .Bl -tag -width PDC_ERR_NOPROC -compact .It PDC_ERR_NOPROC No such procedure .It PDC_ERR_NOPT No such option .It PDC_ERR_COMPL Unable to complete without error .It PDC_ERR_EOD No such device .It PDC_ERR_INVAL Invalid argument .It PDC_ERR_PFAIL Aborted by powerfail .El .Sh SEE ALSO .Xr intro 4 , .Xr io 4 , .Xr lasi 4 .Rs .%T PA-RISC 1.1 Firmware Architecture Reference Specification .%A Hewlett-Packard .%D March 8, 1999 .Re .Rs .%T PA-RISC 2.0 Firmware Architecture Reference Specification .%A Hewlett-Packard .%D March 7, 1999 .Re