.\" $OpenBSD: apmd.8,v 1.41 2009/10/22 15:02:12 sobrado Exp $ .\" .\" Copyright (c) 1995 John T. Kohl .\" All rights reserved. .\" .\" Redistribution and use in source and binary forms, with or without .\" modification, are permitted provided that the following conditions .\" are met: .\" 1. Redistributions of source code must retain the above copyright .\" notice, this list of conditions and the following disclaimer. .\" 2. Redistributions in binary form must reproduce the above copyright .\" notice, this list of conditions and the following disclaimer in the .\" documentation and/or other materials provided with the distribution. .\" 3. The name of the author may not be used to endorse or promote products .\" derived from this software without specific prior written permission. .\" .\" THIS SOFTWARE IS PROVIDED BY THE AUTHOR `AS IS'' AND ANY EXPRESS OR .\" IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED .\" WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE .\" DISCLAIMED. IN NO EVENT SHALL THE AUTHOR BE LIABLE FOR ANY DIRECT, .\" INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES .\" (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR .\" SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) .\" HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, .\" STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN .\" ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE .\" POSSIBILITY OF SUCH DAMAGE. .\" .Dd $Mdocdate: October 22 2009 $ .Dt APMD 8 .Os .Sh NAME .Nm apmd .Nd Advanced Power Management daemon .Sh SYNOPSIS .Nm apmd .Op Fl AaCdHLs .Op Fl f Ar devname .Op Fl S Ar sockname .Op Fl t Ar seconds .Sh DESCRIPTION .Nm monitors the advanced power management device, .Xr apm 4 , acting on signaled events and upon user requests as sent by the .Xr apm 8 program. .Pp For suspend and standby request events delivered by the BIOS, or via .Xr apm 8 , .Nm runs the appropriate configuration program (if one exists), syncs the buffer cache to disk and initiates the requested state. When resuming after suspend or standby, .Nm runs the appropriate configuration program (if one exists). .Pp When the power status changes (battery is connected or disconnected) .Nm fetches the current status and reports it via .Xr syslog 3 with logging facility .Dv LOG_DAEMON . .Pp The options are as follows: .Bl -tag -width Ds .It Fl A Start .Nm in automatic performance adjustment mode. In this mode, when CPU idle time falls below 10%, or if the AC power is connected and the battery is more than 15% charged, .Nm raises .Va hw.setperf to 100. Otherwise when CPU idle time is above 30% and the system is running on battery power, .Nm lowers .Va hw.setperf as much as possible to reduce power consumption. .It Fl a BIOS-initiated suspend or standby requests are ignored if the system is connected to line current and not running from batteries (user requests are still honored). .It Fl C Start .Nm in cool running performance adjustment mode. In this mode, when CPU idle time falls below 10%, .Nm raises .Va hw.setperf as much as necessary. Otherwise when CPU idle time is above 30%, .Nm lowers .Va hw.setperf as much as possible to reduce heat, noise, and power consumption. .It Fl d .Nm enters debug mode, logging to facility .Dv LOG_LOCAL1 , and stays in the foreground on the controlling terminal. .It Fl f Ar devname Specify an alternate device file name, .Ar devname . .It Fl H Start .Nm in manual performance adjustment mode, initialising .Va hw.setperf to 100. .It Fl L Start .Nm in manual performance adjustment mode, initialising .Va hw.setperf to 0. .It Fl S Ar sockname Specify an alternate socket name, .Ar sockname . The socket is protected to mode 0660, UID 0, GID 0; this protects access to suspend requests to authorized users only. .It Fl s Current battery statistics are reported via .Xr syslog 3 and .Nm exits without monitoring the APM status. .It Fl t Ar seconds .Nm periodically polls the APM driver for the current power state. If the battery charge level changes substantially or the external power status changes, the new status is logged. The polling rate defaults to once per 10 minutes, but may be specified using the .Fl t command-line flag. .El .Pp When a client requests a suspend or stand-by state, .Nm does not wait for positive confirmation that the requested state has been entered before replying to the client; to do so would mean the client does not get a reply until the system resumes from its sleep state. Rather, .Nm replies with the intended state to the client and then places the system in the requested state after running the configuration script and flushing the buffer cache. .Pp Actions can be configured for the following five transitions: suspend, standby, resume, powerup, and powerdown. The suspend and standby actions are run prior to .Nm performing any other actions (such as disk syncs) and entering the new state. The resume program is run after resuming from a stand-by or suspended state. The powerup and powerdown programs are run after the power status (AC connected or not) changes, as well as after a resume (if the power status changed in the mean time). .Sh FILES .Bl -tag -width "/etc/apm/powerdownXX" -compact .It /dev/apmctl Default device used to control the APM kernel driver. .Pp .It /etc/apm/suspend .It /etc/apm/standby .It /etc/apm/resume .It /etc/apm/powerup .It /etc/apm/powerdown These files contain the host's customized actions. Each file must be an executable binary or shell script. A single program or script can be used to control all transitions by examining its argument list, which is set to one of suspend, standby, resume, powerup, or powerdown. .Pp .It /var/run/apmdev Default .Ux Ns -domain socket used for communication with .Xr apm 8 . .El .Sh SEE ALSO .Xr syslog 3 , .Xr apm 4 , .Xr apm 8 , .Xr sysctl 8 .Pp Advanced Power Management (APM) BIOS Interface Specification (revision 1.2), Intel Corporation and Microsoft Corporation. .Sh HISTORY The .Nm command first appeared in .Nx 1.3 . .Ox support was added in .Ox 1.2 .