.\" $OpenBSD: snmpd.conf.5,v 1.58 2021/09/02 05:41:02 martijn Exp $ .\" .\" Copyright (c) 2007, 2008, 2012 Reyk Floeter .\" .\" Permission to use, copy, modify, and distribute this software for any .\" purpose with or without fee is hereby granted, provided that the above .\" copyright notice and this permission notice appear in all copies. .\" .\" THE SOFTWARE IS PROVIDED "AS IS" AND THE AUTHOR DISCLAIMS ALL WARRANTIES .\" WITH REGARD TO THIS SOFTWARE INCLUDING ALL IMPLIED WARRANTIES OF .\" MERCHANTABILITY AND FITNESS. IN NO EVENT SHALL THE AUTHOR BE LIABLE FOR .\" ANY SPECIAL, DIRECT, INDIRECT, OR CONSEQUENTIAL DAMAGES OR ANY DAMAGES .\" WHATSOEVER RESULTING FROM LOSS OF USE, DATA OR PROFITS, WHETHER IN AN .\" ACTION OF CONTRACT, NEGLIGENCE OR OTHER TORTIOUS ACTION, ARISING OUT OF .\" OR IN CONNECTION WITH THE USE OR PERFORMANCE OF THIS SOFTWARE. .\" .Dd $Mdocdate: September 2 2021 $ .Dt SNMPD.CONF 5 .Os .Sh NAME .Nm snmpd.conf .Nd Simple Network Management Protocol daemon configuration file .Sh DESCRIPTION .Nm is the configuration file for the .Xr snmpd 8 daemon. .Pp The .Nm file is divided into the following main sections: .Bl -tag -width xxxx .It Sy Macros User-defined variables may be defined and used later, simplifying the configuration file. .It Sy Global Configuration Global runtime settings for .Xr snmpd 8 . .It Sy User Configuration USM user definitions. .It Sy OID Configuration Custom configuration of SNMP object identifiers and values. .El .Pp The current line can be extended over multiple lines using a backslash .Pq Sq \e . Comments can be put anywhere in the file using a hash mark .Pq Sq # , and extend to the end of the current line. Care should be taken when commenting out multi-line text: the comment is effective until the end of the entire block. .Pp Argument names not beginning with a letter, digit, or underscore must be quoted. .Pp Additional configuration files can be included with the .Ic include keyword, for example: .Bd -literal -offset indent include "/etc/snmpd.conf.local" .Ed .Sh MACROS Macros can be defined that will later be expanded in context. Macro names must start with a letter, digit, or underscore, and may contain any of those characters. Macro names may not be reserved words (for example, .Ic community , .Ic system , or .Ic oid ) . Macros are not expanded inside quotes. .Pp For example: .Bd -literal -offset indent ext_addr="192.168.0.1" listen on $ext_addr .Ed .Sh GLOBAL CONFIGURATION The following options can be set globally: .Bl -tag -width Ds .It Ic filter-pf-addresses Pq Ic yes | no If set to .Ic yes , .Xr snmpd 8 will filter out the OPENBSD-PF-MIB::pfTblAddrTable tree. Addresses stored in PF tables will not be available, but CPU use will be reduced during bulk walks. The default is .Ic no . .It Ic filter-routes Pq Ic yes | no If set to .Ic yes , ask the kernel to filter route update messages on the routing socket. Routing table information will not be available, but CPU use will be reduced during bulk updates. The default is .Ic no . .It Ic listen on Oo Ic tcp | udp Oc Ar address Oo Ic port Ar port Oc Op Ar flags Specify the local .Ar address .Xr snmpd 8 should listen on for incoming SNMP messages, or .Cm any to listen on all local IPv4 and IPv6 addresses. Multiple .Ic listen on statements are supported. If no .Ic listen on statement is present, the default is .Ic listen on Cm any . .Pp The .Ar flags are as follows: .Bl -tag -width Ds .It Ic read Accept get, getnext and bulkget requests. .It Ic write Accepts set requests. .It Ic notify Accepts trapv1 and trapv2 requests. .It Ic snmpv1 Enable SNMPv1 subsystem on the listen address. .It Ic snmpv2c Enable SNMPv2c subsystem on the listen address. .It Ic snmpv3 Enable SNMPv3 subsystem on the listen address. .El .Pp The default protocol is .Ic udp . The default .Ar port is 161, unless .Ic notify is the only permission flag; which sets the .Ar port to 162. If no permission flags are specified it defaults to .Dq Ic read Ic write , or .Ic notify when .Ar port is 162. If no subsystem flags are specified it defaults to .Ic snmpv3 . .Pp Having .Ic notify set requires at least one .Ic trap handle statement. .It Ic engineid Oo Ic pen Ar enterprise Oc Ar format Set the snmp engineid, used for instance identification and key generation for the .Ic user .Ar auth and .Ar key . .Ar enterprise specifies the private enterprise number of the instance and can be either an integer or .Ic openbsd .Pq default . .Pp .Ar format can be one of the following: .Bl -tag -width Ds .It Ic ipv4 Ar address The engineID's format identifier is set to 1 and the ipv4 .Ar address is used in the format. .It Ic ipv6 Ar address The engineID's format identifier is set to 2 and the ipv6 .Ar address is used in the format. .It Ic mac Ar address The engineID's format identifier is set to 3 and the mac .Ar address is used in the format. .It Ic text Ar text The engineID's format identifier is set to 4 and the ASCII .Ar text is used in the format. .It Ic octets Ar octetstring The engineID's format identifier is set to 5 and the .Ar octetstring in hexadecimal is used in the format. .It Ic hosthash Op Ar hostname The engineID's format identifier is set to 129 and the first 27 bytes of the sha256 hash of the .Ar hostname are used in the format. This option is only valid for .Ar enterprise .Ic openbsd . If used for the local engineID, then .Ar hostname defaults to the value of .Xr hostname 1 . This format is the default. .It Ar number Ar octetstring The engineID's format identifier is set to .Ar number and the .Ar octetstring in hexadecimal is used in the format. This format is only available if .Ar enterprise is not .Ic openbsd . .It Ic agentid Ar octetstring RFC1910 legacy format. .Ar octetstring must be 8 bytes .Pq or 16 characters in hexadecimal format . .El .It Ic read-only community Ar string Specify the name of the read-only community. There is no default value. .It Ic read-write Ic community Ar string Specify the name of the read-write community. There is no default value. .It Ic seclevel Pq Ic none | auth | enc Specify the lowest security level that .Xr snmpd 8 accepts on SNMPv3: .Bl -tag -width "auth" -offset ident .It Ic none Both authentication and encryption of messages is optional. .It Ic auth Authentication of messages is mandatory. .Xr snmpd 8 will discard any messages that don't have a valid digest. Encryption of messages is optional. .It Ic enc Messages must be encrypted and must have a valid digest for authentication. Otherwise they will be discarded. This is the default value. .El .It Ic system contact Ar string Specify the name or description of the system contact, typically a name or an email address. The default value is .Ar root@hostname using the hostname of the local machine. .It Ic system description Ar string Specify a description of the local system. The default value is the operating system identification as printed by the .Xr uname 1 command using the .Fl a flag: .Bd -literal -offset indent OpenBSD myhost.example.com 4.2 GENERIC#595 i386 .Ed .It Ic system location Ar string Specify the string describing the location of the local system, typically a physical location. The default value is an empty string. .It Ic system name Ar string Specify the name of the local system, typically a fully-qualified domain name. The default value is the hostname of the local system. .It Ic system oid Ar oid-string Specify the authoritative identification of the local system. The default value is .Ar 1.3.6.1.4.1.30155.23.1 .Pq iso.org.dod.internet.private.enterprises.openbsd.23.1 identifying a common .Ox system. .It Ic system services Ar number Specify a magic value which indicates the set of services that the local system may provide. Refer to the .Ar sysServices description in the SNMP MIB for details. The value is given in decimal. .\"XXX describe the complicated services alg here .It Ic trap community Ar string Specify the name of the trap community. There is no default value. .It Ic trap handle Ar oid Qq Ar command Execute .Ic command upon receipt of an SNMP trap that begins with a prefix of .Ic oid . Alternately, the string .Qq Ic default may be used, in which case the prefix used is .Ic 1.3 . The invoked .Ar command will receive the following information about the trap on standard input, one per line, in this order: the resolved hostname of the host sending the trap, the IP address of the host sending the trap, and any variable bindings contained in the trap (the OID followed by the value, separated by a single space). This option requires at least one .Ic listen on statement with a .Ic notify flag set. Traps over SNMPv3 are currently unsupported. .It Xo .Ic trap receiver Ar address .Op Ic oid Ar oid-string .Ic snmpv2c .Op Ic community Ar string .Op Ic source-address Ar address .Xc Specify the .Ar address or FQDN of a remote trap receiver for outgoing traps sent by .Xr snmpd 8 . This option may be specified multiple times. The daemon will send outgoing traps in .Ic snmpv2c format. The default community is specified by the global .Ic trap community option. The IPv4 or IPv6 source address of the traps can be enforced using .It Xo .Ic trap receiver Ar address .Op Ic oid Ar oid-string .Op Ic snmpv3 .Ic user Ar name Oo Ic seclevel Ar level Oc .Op Ic source-address Ar address .Xc Specify the .Ar address or FQDN of a remote trap receiver for outgoing traps sent by .Xr snmpd 8 . This option may be specified multiple times. The daemon will send outgoing traps in .Ic snmpv3 format. .Ic user must point to an existing global .Ic user . If .Ic seclevel is not defined it defaults to the global .Ic seclevel option. The IPv4 or IPv6 source address of the traps can be enforced using .Ic source-address . .El .Sh USER CONFIGURATION Users for the SNMP User-based Security Model (USM, RFC 3414) must be defined in the configuration file: .Bl -tag -width xxxx .It Xo .Ic user Ar name .Op Ic authkey Ar key Ic auth Ar hmac .Op Ic enckey Ar key Ic enc Ar cipher .Xc Defines a known user. The .Ic authkey keyword is required to specify the digest key used to authenticate messages. If this keyword is omitted then authentication is disabled for this user account. Optionally the HMAC algorithm used for authentication can be specified. .Ar hmac must be either .Ic hmac-md5 , .Ic hmac-sha1 , .Ic hmac-sha224 , .Ic hmac-sha256 , .Ic hmac-sha384 , or .Ic hmac-sha512 . If omitted the default is .Ic hmac-sha1 . .Pp With .Ic enckey the encryption key used to encrypt and decrypt messages for privacy is defined. Without an .Ic enckey specification the user account will neither accept encrypted incoming messages nor will it encrypt outgoing messages. The .Ar enc algorithm can be either .Ic des or .Ic aes and defaults to .Ic aes . .Pp Any user account that has encryption enabled requires authentication to be enabled too. .El .Sh OID CONFIGURATION It is possible to specify user-defined OIDs in the configuration file: .Bl -tag -width Ds .It Xo .Ic oid Ar oid-string .Ic name Ar name .Op Ic read-only | read-write .Op Ar type .Ar value .Xc Return the specified value to the client for this OID. The .Ic read-write option may allow the client to override it, and the type is either .Ic string or .Ic integer . .El .Sh FILES .Bl -tag -width /etc/examples/snmpd.conf -compact .It Pa /etc/snmpd.conf Default location of the configuration file. .It Pa /etc/examples/snmpd.conf Example configuration file. .El .Sh EXAMPLES The following example will tell .Xr snmpd 8 to listen on localhost for SNMPv2c messages only with the community .Dq 8LHQtm1QLGzk , override the default system OID, set the magic services value, and provide some custom OID values: .Bd -literal -offset indent listen on 127.0.0.1 snmpv2c read-only community 8LHQtm1QLGzk system oid 1.3.6.1.4.1.30155.23.2 system services 74 oid 1.3.6.1.4.1.30155.42.1 name myName read-only string "humppa" oid 1.3.6.1.4.1.30155.42.2 name myStatus read-only integer 1 .Ed .Pp The next example will enforce SNMPv3 with authenticated and encrypted communication and the user-based security model. The configuration defines several users using varying encryption and authentication algorithms. .Bd -literal -offset indent seclevel enc user "mgmt" auth hmac-sha256 authkey "password123" enc aes enckey "321drowssap" user "hans" auth hmac-sha1 authkey "password456" enc aes enckey "654drowssap" user "sophie" auth hmac-md5 authkey "password789" enc des enckey "987drowssap" .Ed .Sh SEE ALSO .Xr snmp 1 , .Xr snmpd 8 .Sh HISTORY The .Nm file format first appeared in .Ox 4.3 . .Sh AUTHORS The .Xr snmpd 8 program was written by .An Reyk Floeter Aq Mt reyk@openbsd.org .