1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
|
.\" $OpenBSD: bge.4,v 1.30 2006/06/27 16:40:11 brad Exp $
.\" Copyright (c) 2001 Wind River Systems
.\" Copyright (c) 1997, 1998, 1999, 2000, 2001
.\" Bill Paul <wpaul@windriver.com>. All rights reserved.
.\"
.\" Redistribution and use in source and binary forms, with or without
.\" modification, are permitted provided that the following conditions
.\" are met:
.\" 1. Redistributions of source code must retain the above copyright
.\" notice, this list of conditions and the following disclaimer.
.\" 2. Redistributions in binary form must reproduce the above copyright
.\" notice, this list of conditions and the following disclaimer in the
.\" documentation and/or other materials provided with the distribution.
.\" 3. All advertising materials mentioning features or use of this software
.\" must display the following acknowledgement:
.\" This product includes software developed by Bill Paul.
.\" 4. Neither the name of the author nor the names of any co-contributors
.\" may be used to endorse or promote products derived from this software
.\" without specific prior written permission.
.\"
.\" THIS SOFTWARE IS PROVIDED BY Bill Paul AND CONTRIBUTORS ``AS IS'' AND
.\" ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
.\" IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
.\" ARE DISCLAIMED. IN NO EVENT SHALL Bill Paul OR THE VOICES IN HIS HEAD
.\" BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR
.\" CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF
.\" SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS
.\" INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN
.\" CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE)
.\" ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF
.\" THE POSSIBILITY OF SUCH DAMAGE.
.\"
.Dd September 27, 2001
.Dt BGE 4
.Os
.Sh NAME
.Nm bge
.Nd Broadcom BCM57xx/BCM590x Ethernet adapter driver
.Sh SYNOPSIS
.Cd "bge* at pci?"
.Cd "brgphy* at mii?"
.Sh DESCRIPTION
The
.Nm
driver provides support for various NICs based on the Broadcom BCM570x,
571x, 572x, 575x and 578x families of Gigabit Ethernet controller
chips and the 590x family of Fast Ethernet controller chips, including
the following:
.Pp
.Bl -bullet -compact
.It
3Com 3c996-T (10/100/1000baseT)
.It
3Com 3c996-SX (1000baseSX)
.It
3Com 3c996B-T (10/100/1000baseT)
.It
Dell PowerEdge 1750 integrated BCM5704C NIC (10/100/1000baseT)
.It
Dell PowerEdge 2550 integrated BCM5700 NIC (10/100/1000baseT)
.It
Dell PowerEdge 2650 integrated BCM5703 NIC (10/100/1000baseT)
.It
HP ProLiant NC320T PCI-E Gigabit NIC (10/100/1000baseT)
.It
HP ProLiant NC370F PCI-X Gigabit NIC (1000baseSX)
.It
HP ProLiant NC370T PCI-X Gigabit NIC (10/100/1000baseT)
.It
HP ProLiant NC1020 PCI Gigabit NIC (10/100/1000baseT)
.It
HP ProLiant NC6770 PCI-X Gigabit NIC (1000baseSX)
.It
HP ProLiant NC7760 embedded PCI Gigabit NIC (10/100/1000baseT)
.It
HP ProLiant NC7770 PCI-X Gigabit NIC (10/100/1000baseT)
.It
HP ProLiant NC7771 PCI-X Gigabit NIC (10/100/1000baseT)
.It
HP ProLiant NC7780 embedded PCI-X Gigabit NIC (10/100/1000baseT)
.It
HP ProLiant NC7781 embedded PCI-X Gigabit NIC (10/100/1000baseT)
.It
HP ProLiant NC7782 embedded PCI-X Gigabit NIC (10/100/1000baseT)
.It
IBM xSeries 235 integrated BCM5703X NIC (10/100/1000baseT)
.It
IBM xSeries 305 integrated BCM5703X NIC (10/100/1000baseT)
.It
Netgear GA302T (10/100/1000baseT)
.It
SysKonnect SK-9D21 (10/100/1000baseT)
.It
SysKonnect SK-9D41 (1000baseSX)
.El
.Pp
All of these NICs are capable of 10, 100 speeds over CAT5 copper cable;
the Gigabit controller chips also support 1000Mbps, except for the
SysKonnect SK-9D41 which supports only 1000Mbps over multimode fiber.
It has two R4000 CPU cores and is PCI v2.2 and PCI-X v1.0 compliant.
It supports
.\"IP, TCP
.\"and UDP checksum offload for both receive and transmit,
multiple RX and TX DMA rings for QoS applications, rules-based
receive filtering, and VLAN tag stripping/insertion as well as
a 256-bit multicast hash filter.
Additional features may be provided via value-add firmware updates.
The BCM57xx supports TBI (ten bit interface) and GMII transceivers, which
means it can be used with either copper or 1000baseX fiber applications.
Note however the device only supports a single speed in TBI mode.
.Pp
Most BCM5700-based cards also use the Broadcom BCM5401 or BCM5411 10/100/1000
copper Gigabit transceivers,
which support autonegotiation of 10, 100 and 1000Mbps modes in
full or half duplex.
.Pp
The BCM5700, BCM5701, BCM5703 and BCM5704 are capable of supporting Jumbo frames,
which can be configured via the interface MTU setting.
Selecting an MTU larger than 1500 bytes with the
.Xr ifconfig 8
utility configures the adapter to receive and transmit Jumbo frames.
Using Jumbo frames can greatly improve performance for certain tasks,
such as file transfers and data streaming.
.Pp
The
.Nm
driver supports the following media types:
.Bl -tag -width 1000baseSX
.It Cm autoselect
Enable autoselection of the media type and options.
The user can manually override
the autoselected mode by adding media options to the appropriate
.Xr hostname.if 5
file.
.It Cm 10baseT
Set 10Mbps operation.
The
.Xr ifconfig 8
.Ic mediaopt
option can also be used to select either
.Cm full-duplex
or
.Cm half-duplex
modes.
.It Cm 100baseTX
Set 100Mbps (Fast Ethernet) operation.
The
.Xr ifconfig 8
.Ic mediaopt
option can also be used to select either
.Cm full-duplex
or
.Cm half-duplex
modes.
.It Cm 1000baseT
Set 1000baseT operation over twisted pair.
Only
.Cm full-duplex
mode is supported.
.It Cm 1000baseSX
Set 1000Mbps (Gigabit Ethernet) operation.
Both
.Cm full-duplex
and
.Cm half-duplex
modes are supported.
.El
.Pp
The
.Nm
driver supports the following media options:
.Bl -tag -width full-duplex
.It Cm full-duplex
Force full duplex operation.
.It Cm half-duplex
Force half duplex operation.
.El
.Pp
The
.Nm
driver also supports one special link option for 1000baseT cards:
.Bl -tag -width link0
.It Cm link0
With 1000baseT cards, establishing a link between two ports requires
that one port be configured as a master and the other a slave.
With autonegotiation,
the master/slave settings will be chosen automatically.
However when manually selecting the link state, it is necessary to
force one side of the link to be a master and the other a slave.
The
.Nm
driver configures the ports as slaves by default.
Setting the
.Cm link0
flag with
.Xr ifconfig 8
will set a port as a master instead.
.El
.Pp
For more information on configuring this device, see
.Xr ifconfig 8 .
.Sh DIAGNOSTICS
.Bl -diag
.It "bge%d: can't find mem space"
A fatal initialization error has occurred.
.It "bge%d: couldn't map interrupt"
A fatal initialization error has occurred.
.It "bge%d: no memory for jumbo buffer queue!"
The driver failed to allocate memory for jumbo frames during
initialization.
.It "bge%d: watchdog timeout"
The device has stopped responding to the network, or there is a problem with
the network connection (cable).
.El
.Sh SEE ALSO
.Xr arp 4 ,
.Xr brgphy 4 ,
.Xr ifmedia 4 ,
.Xr intro 4 ,
.Xr netintro 4 ,
.Xr pci 4 ,
.Xr hostname.if 5 ,
.Xr ifconfig 8
.Sh HISTORY
The
.Nm
device driver first appeared in
.Ox 3.0 .
.Sh AUTHORS
The
.Nm
driver was written by
.An Bill Paul Aq wpaul@windriver.com .
|