blob: 15c0fcf0f922776e80ee6f1a41b444b262164a65 (
plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
|
# $OpenBSD: GENERIC,v 1.45 2005/04/30 00:36:05 deraadt Exp $
#
# For further information on compiling OpenBSD kernels, see the config(8)
# man page.
#
# For further information on hardware support for this architecture, see
# the intro(4) man page. For further information about kernel options
# for this architecture, see the options(4) man page. For an explanation
# of each device driver in this file see the section 4 man page for the
# device.
machine mvme88k m88k
include "../../../conf/GENERIC"
# Processor type
option M88100
option M88110
option MVME187 # support for 187 (requires M88100)
option MVME188 # support for 188 (requires M88100)
option MVME197 # support for 197 (requires M88110)
option "NCPUS=1" # number of CPUs supported (max 4)
# Define this if your processor has the xxx.usr bug (mask C82N)
option ERRATA__XXX_USR
maxusers 64
config bsd swap generic
#
# devices
#
mainbus0 at root
bugtty0 at mainbus0
# MVME1x7 devices
pcctwo0 at mainbus0 addr 0xfff00000 # MVME187
bussw0 at mainbus0 addr 0xfff00000 # MVME197
sram0 at mainbus0 addr 0xffe00000 # MVME187
pcctwo0 at bussw0 offset 0x00000 # MVME197
clock0 at pcctwo0 ipl 5
nvram0 at pcctwo0 offset 0xc0000
vme0 at pcctwo0 offset 0x40000
ie0 at pcctwo0 offset 0x46000 ipl 1
osiop0 at pcctwo0 offset 0x47000 ipl 2
cl0 at pcctwo0 offset 0x45000 ipl 3
cl1 at pcctwo0 offset 0x45200 ipl 3 # M8120 only
#lptwo0 at pcctwo0 offset 0x45000 ipl 1
memc0 at pcctwo0 offset 0x43000
memc1 at pcctwo0 offset 0x43100
# MVME188 devices
syscon0 at mainbus0 addr 0xfff00000 # MVME188
clock0 at syscon0 ipl 5
nvram0 at syscon0 offset 0x80000
dart0 at syscon0 offset 0x82000 ipl 3
vme0 at syscon0 offset 0x85000
vmes0 at vme0
vmel0 at vme0
vx0 at vmes0 addr 0xff780000 ipl 3
vx1 at vmes0 addr 0xff790000 ipl 3
vx2 at vmes0 addr 0xff7a0000 ipl 3
vx3 at vmes0 addr 0xff7b0000 ipl 3
le0 at vmes0 addr 0xffff1200 ipl 1
le1 at vmes0 addr 0xffff1400 ipl 1
le2 at vmes0 addr 0xffff1600 ipl 1
vs0 at vmes0 addr 0xffff9000 ipl 2
vs1 at vmes0 addr 0xffff9800 ipl 2
vs2 at vmes0 addr 0xffff4800 ipl 2
vs3 at vmes0 addr 0xffff5800 ipl 2
vs4 at vmes0 addr 0xffff7000 ipl 2
vs5 at vmes0 addr 0xffff7800 ipl 2
scsibus* at vs?
scsibus* at osiop?
sd* at scsibus?
st* at scsibus?
cd* at scsibus?
ch* at scsibus?
ss* at scsibus?
uk* at scsibus?
|