1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
|
/*
* Copyright (c) 1995 Mats O Jansson. All rights reserved.
*
* Redistribution and use in source and binary forms, with or without
* modification, are permitted provided that the following conditions
* are met:
* 1. Redistributions of source code must retain the above copyright
* notice, this list of conditions and the following disclaimer.
* 2. Redistributions in binary form must reproduce the above copyright
* notice, this list of conditions and the following disclaimer in the
* documentation and/or other materials provided with the distribution.
* 3. All advertising materials mentioning features or use of this software
* must display the following acknowledgement:
* This product includes software developed by Mats O Jansson.
* 4. The name of the author may not be used to endorse or promote products
* derived from this software without specific prior written permission.
*
* THIS SOFTWARE IS PROVIDED BY THE AUTHOR ``AS IS'' AND ANY EXPRESS OR
* IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES
* OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED.
* IN NO EVENT SHALL THE AUTHOR BE LIABLE FOR ANY DIRECT, INDIRECT,
* INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT
* NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE,
* DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY
* THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT
* (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF
* THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
*
* $Id: nmadef.h,v 1.1 1996/09/21 13:49:16 maja Exp $
*
*/
#ifndef _NMADEF_H_
#define _NMADEF_H_
#define NMA_C_SOFD_DP 0 /* DP11-DA */
#define NMA_C_SOFD_UNA 1 /* DEUNA */
#define NMA_C_SOFD_DU 2 /* DU11-DA */
#define NMA_C_SOFD_CNA 3 /* DECNA */
#define NMA_C_SOFD_DL 4 /* DL11-C, -E, or -WA */
#define NMA_C_SOFD_QNA 5 /* DEQNA */
#define NMA_C_SOFD_DQ 6 /* DQ11-DA */
#define NMA_C_SOFD_CI 7 /* Computer Interconnect */
#define NMA_C_SOFD_DA 8 /* DA11-B or -AL */
#define NMA_C_SOFD_PCL 9 /* PCL11-B */
#define NMA_C_SOFD_DUP 10 /* DUP11-DA */
#define NMA_C_SOFD_LUA 11 /* DELUA */
#define NMA_C_SOFD_DMC 12 /* DMC11-DA/AR, -FA/AR, -MA/AL or -MD/AL */
#define NMA_C_SOFD_LNA 13 /* MicroServer Lance */
#define NMA_C_SOFD_DN 14 /* DN11-BA or -AA */
#define NMA_C_SOFD_DLV 16 /* DLV11-E, -F, -J, MXV11-A or -B */
#define NMA_C_SOFD_LCS 17 /* DECServer 100 */
#define NMA_C_SOFD_DMP 18 /* DMP11 */
#define NMA_C_SOFD_AMB 19 /* AMBER */
#define NMA_C_SOFD_DTE 20 /* DTE20 */
#define NMA_C_SOFD_DBT 21 /* DEBET */
#define NMA_C_SOFD_DV 22 /* DV11-AA/BA */
#define NMA_C_SOFD_BNA 23 /* DEBNA */
#define NMA_C_SOFD_BNT 23 /* DEBNT */
#define NMA_C_SOFD_DZ 24 /* DZ11-A, -B, -C, -D */
#define NMA_C_SOFD_LPC 25 /* PCXX */
#define NMA_C_SOFD_DSV 26 /* DSV11 */
#define NMA_C_SOFD_CEC 27 /* 3-COM/IBM-PC */
#define NMA_C_SOFD_KDP 28 /* KMC11/DUP11-DA */
#define NMA_C_SOFD_IEC 29 /* Interlan/IBM-PC */
#define NMA_C_SOFD_KDZ 30 /* KMC11/DZ11-A, -B, -C, or -D */
#define NMA_C_SOFD_UEC 31 /* Univation/RAINBOW-100 */
#define NMA_C_SOFD_KL8 32 /* KL8-J */
#define NMA_C_SOFD_DS2 33 /* DECServer 200 */
#define NMA_C_SOFD_DMV 34 /* DMV11 */
#define NMA_C_SOFD_DS5 35 /* DECServer 500 */
#define NMA_C_SOFD_DPV 36 /* DPV11 */
#define NMA_C_SOFD_LQA 37 /* DELQA */
#define NMA_C_SOFD_DMF 38 /* DMF32 */
#define NMA_C_SOFD_SVA 39 /* DESVA */
#define NMA_C_SOFD_DMR 40 /* DMR11-AA, -AB, -AC, or -AE */
#define NMA_C_SOFD_MUX 41 /* MUXserver */
#define NMA_C_SOFD_KMY 42 /* KMS11-PX */
#define NMA_C_SOFD_DEP 43 /* DEPCA PCSG/IBM-PC */
#define NMA_C_SOFD_KMX 44 /* KMS11-BD/BE */
#define NMA_C_SOFD_LTM 45 /* LTM Ethernet monitor */
#define NMA_C_SOFD_DMB 46 /* DMB-32 */
#define NMA_C_SOFD_DES 47 /* DESNC */
#define NMA_C_SOFD_KCP 48 /* KCP */
#define NMA_C_SOFD_MX3 49 /* MUXServer 300 */
#define NMA_C_SOFD_SYN 50 /* MicroServer */
#define NMA_C_SOFD_MEB 51 /* DEMEB */
#define NMA_C_SOFD_DSB 52 /* DSB32 */
#define NMA_C_SOFD_BAM 53 /* DEBAM LANBridge-200 */
#define NMA_C_SOFD_DST 54 /* DST-32 TEAMmate */
#define NMA_C_SOFD_FAT 55 /* DEFAT */
#define NMA_C_SOFD_RSM 56 /* DERSM - Remote Segment Monitor */
#define NMA_C_SOFD_RES 57 /* DERES - Remote Environmental Sensor */
#define NMA_C_SOFD_3C2 58 /* 3COM Etherlink II (3C503) */
#define NMA_C_SOFD_3CM 59 /* 3COM Etherlink/MC (3C523) */
#define NMA_C_SOFD_DS3 60 /* DECServer 300 */
#define NMA_C_SOFD_MF2 61 /* Mayfair-2 */
#define NMA_C_SOFD_MMR 62 /* DEMMR */
#define NMA_C_SOFD_VIT 63 /* Vitalink TransLAN III/IV (NP3A) Bridge */
#define NMA_C_SOFD_VT5 64 /* Vitalink TransLAN 350 (NPC25) Bridge */
#define NMA_C_SOFD_BNI 65 /* DEBNI */
#define NMA_C_SOFD_MNA 66 /* DEMNA */
#define NMA_C_SOFD_PMX 67 /* PMAX (KN01) */
#define NMA_C_SOFD_NI5 68 /* Interlan NI5210-8 */
#define NMA_C_SOFD_NI9 69 /* Interlan NI9210 */
#define NMA_C_SOFD_KMK 70 /* KMS11-K */
#define NMA_C_SOFD_3CP 71 /* 3COM Etherlink Plus (3C505) */
#define NMA_C_SOFD_DP2 72 /* DPNserver-200 */
#define NMA_C_SOFD_ISA 73 /* SGEC */
#define NMA_C_SOFD_DIV 74 /* DIV-32 DEC WAN controller-100 */
#define NMA_C_SOFD_QTA 75 /* DEQTA */
#define NMA_C_SOFD_B15 76 /* LANbridge-150 */
#define NMA_C_SOFD_WD8 77 /* WD8003 Family */
#define NMA_C_SOFD_ILA 78 /* BICC ISOLAN 4110-2 */
#define NMA_C_SOFD_ILM 79 /* BICC ISOLAN 4110-3 */
#define NMA_C_SOFD_APR 80 /* Apricot Xen-S and Qi */
#define NMA_C_SOFD_ASN 81 /* AST EtherNode */
#define NMA_C_SOFD_ASE 82 /* AST Ethernet */
#define NMA_C_SOFD_TRW 83 /* TRW HC-2001 */
#define NMA_C_SOFD_EDX 84 /* Ethernet-XT/AT */
#define NMA_C_SOFD_EDA 85 /* Ethernet-AT */
#define NMA_C_SOFD_DR2 86 /* DECrouter-250 */
#define NMA_C_SOFD_SCC 87 /* DECrouter-250 DUSCC */
#define NMA_C_SOFD_DCA 88 /* DCA Series 300 */
#define NMA_C_SOFD_TIA 89 /* LANcard/E */
#define NMA_C_SOFD_FBN 90 /* DEFEB DECbridge-500 */
#define NMA_C_SOFD_FEB 91 /* DEFEB DECbridge-500 FDDI */
#define NMA_C_SOFD_FCN 92 /* DEFCN DECconcentrator-500 */
#define NMA_C_SOFD_MFA 93 /* DEMFA */
#define NMA_C_SOFD_MXE 94 /* MIPS workstation family */
#define NMA_C_SOFD_CED 95 /* Cabletron Ethernet Desktop */
#define NMA_C_SOFD_C20 96 /* 3Com CS/200 */
#define NMA_C_SOFD_CS1 97 /* 3Com CS/1 */
#define NMA_C_SOFD_C2M 98 /* 3Com CS/210, CS/2000, CS/2100 */
#define NMA_C_SOFD_ACA 99 /* ACA/32000 system */
#define NMA_C_SOFD_GSM 100 /* Gandalf StarMaster */
#define NMA_C_SOFD_DSF 101 /* DSF32 */
#define NMA_C_SOFD_CS5 102 /* 3Com CS/50 */
#define NMA_C_SOFD_XIR 103 /* XIRCOM PE10B2 */
#define NMA_C_SOFD_KFE 104 /* KFE52 */
#define NMA_C_SOFD_RT3 105 /* rtVAX-300 */
#define NMA_C_SOFD_SPI 106 /* Spiderport M250 */
#define NMA_C_SOFD_FOR 107 /* LAT gateway */
#define NMA_C_SOFD_MER 108 /* Meridian */
#define NMA_C_SOFD_PER 109 /* Persoft */
#define NMA_C_SOFD_STR 110 /* AT&T StarLan-10 */
#define NMA_C_SOFD_MPS 111 /* MIPSfair */
#define NMA_C_SOFD_L20 112 /* LPS20 print server */
#define NMA_C_SOFD_VT2 113 /* Vitalink TransLAN 320 Bridge */
#define NMA_C_SOFD_DWT 114 /* VT-1000 */
#define NMA_C_SOFD_WGB 115 /* DEWGB */
#define NMA_C_SOFD_ZEN 116 /* Zenith Z-LAN4000, Z-LAN */
#define NMA_C_SOFD_TSS 117 /* Thursby Software Systems */
#define NMA_C_SOFD_MNE 118 /* 3MIN (KN02-BA) */
#define NMA_C_SOFD_FZA 119 /* DEFZA */
#define NMA_C_SOFD_90L 120 /* DS90L */
#define NMA_C_SOFD_CIS 121 /* Cisco Systems */
#define NMA_C_SOFD_STC 122 /* STRTC */
#define NMA_C_SOFD_UBE 123 /* Ungermann-Bass PC2030, PC3030 */
#define NMA_C_SOFD_DW2 124 /* DECwindows terminal II */
#define NMA_C_SOFD_FUE 125 /* Fujitsu Etherstar MB86950 */
#define NMA_C_SOFD_M38 126 /* MUXServer 380 */
#define NMA_C_SOFD_NTI 127 /* NTI Group PC Ethernet Card */
#define NMA_C_SOFD_RAD 130 /* RADLINX LAN Gateway */
#define NMA_C_SOFD_INF 131 /* Infotron Commix */
#define NMA_C_SOFD_XMX 132 /* Xyplex MAXserver */
#define NMA_C_SOFD_NDI 133 /* NDIS data link driver for MS/DOS systems */
#define NMA_C_SOFD_ND2 134 /* NDIS data link driver for OS/2 systems */
#define NMA_C_SOFD_TRN 135 /* DEC LANcontroller 520 */
#define NMA_C_SOFD_DEV 136 /* Develcon Electronics Ltd. LAT gateway */
#define NMA_C_SOFD_ACE 137 /* Acer 5220, 5270 adapter */
#define NMA_C_SOFD_PNT 138 /* ProNet-4/18 #1390 */
#define NMA_C_SOFD_ISE 139 /* Network Integration Server 600 */
#define NMA_C_SOFD_IST 140 /* Network Integration Server 600 T1 */
#define NMA_C_SOFD_ISH 141 /* Network Integration Server 64 kb HDLC */
#define NMA_C_SOFD_ISF 142 /* Network Integration Server 600 FDDI */
#define NMA_C_SOFD_DSW 149 /* DSW-21 */
#define NMA_C_SOFD_DW4 150 /* DSW-41/42 */
#define NMA_C_SOFD_TRA 175 /* DETRA-AA */
#endif _NMADEF_H_
|